Monday, July 22, 2024

Surge Protection for Home Networks

There are a lot of blogs recommending products you should buy but this time I'm going to start by recommend what you should not buy. 

If you are reading this blog chances are good that you have an Internet service provider, and most of us are using copper based Internet services.  Meaning there's a coaxial cable that comes in from the outside, hooks up to a modem / router and then may go to high performance devices via a copper Ethernet cable.  That copper continuity is the complete surge circuit.   If your provider has an optical fiber to your home you may be in better shape, but long internal Ethernet runs can also pick up a surge. 

 

TL;DR

Don't buy Ethernet surge protectors that connect to ground.  At all.  That includes separate Ethernet surge protectors, rack mounted units and those included with surge strips.  Yes, that includes Furman. 


 

Why not? 

At least a couple of engineering industry newsletters I've seen say the same thing: The presence of grounding Ethernet surge protectors is associated with higher, not lower, chances of surge damage.  The technical argument they make has me convinced me they actually make things worse.  

To make a long story short, there are two types of surges.  Common mode and differential.  Differential is more dangerous as it can cross the transformer boundary at much lower voltages than common mode. These types of surge "protectors" can convert common mode surges into differential.  In addition, common mode surges are (pun not intended) more common or frequent.  So by using these devices you turn a potentially non-issue into a device zapping event. You can read about the research and science in this link.

In a common-mode surge both wires have the same voltage.  In a differential-mode surge the voltage between the two wires is not equal, and this difference in voltage is what can slip through the  transformer.

At the end of each Ethernet wire pair is a tiny transformer.  That transformer has at least 2 kV of  common mode isolation built in.  This means if a 2kV surge is common mode the output of the transformer is still 0 V, or at least severely attenuated below 2kV.  However, a differential surge of practically any voltage can cross the transformer barrier, sending potentially hundreds of volts through your gear until it finds a path to ground.  A hundred or two hundred volts on the equipment side of the transformer will happily jump through micrometer sized solid state elements burning up everything in it's path.  Remember, most surge damage isn't even visible.

 

Research Has Been Slow

Knowledge and research on Ethernet surge protection has been slow in coming in large part because Ethernet surge damage is pretty rare, and users of Ethernet surge protectors even more rare.  Also, the damage per incident is low vs. say a house fire or traffic accident.  Damage to your TV is just not going to be reported or investigated the way a house fire would be.  Even significant damage in a data center doesn't usually make the news.  As a result of this a lot of surge strips with Ethernet protection are 20 years behind the latest research, or more.

Further complications arise in that there are at least three major failure/surge patterns which are discussed.  The one thing that IS pretty clear is to avoid these types of surge protectors. 

Having said this, I've had multiple surge events enter my home from outside coaxial sources, and I have a lot of gear I can't afford to replace hooked up to Ethernet cables so for me network surge protection is not optional.  I remind my readers that damaging surges are rarely visible or dramatic.  Those who think electrical surges only happen when there is smoke coming from your carbonized roof will never understand the fully justified paranoia of being a videophile and IT worker in storm prone areas. 


What are my alternatives?

External Coaxial Protection 

Outside my home at the grounding block where the cable provider's cable ends and my internal coaxial begins I use a surge arrestor with a 90V gas discharge tube.  In my experience the units are not perfect but they lower the surge voltage so that it is very unlikely to jump through multiple devices.  Also, note that while this is a grounding arrestor it won't cause a common to differential mode conversion unlike a grounding Ethernet surge protector.

If you have any external antennas you should absolutely use one of these for each of them as close to if not ON the required external grounding block.  

In the Boston area we had ferocious wind storms which took out our DirecTV receiver multiple times until I put one of these units in.  It seems those antennas are susceptible to developing a static charge due to the wind rubbing off electrons on the surface and then zap!! Yes, the cable was already grounded.  Didn't help as much as one of these units.  Also, there was no visible damage nor was there any smell.  All we knew is that the receiver no longer received and this would happen suddenly after a long gust of wind.  That should be a good indicator of how small an event can destroy sensitive equipment.

From a variety of sources I've been discouraged from using coax protectors that come with surge strips as the quality is variable and often degrades the signal and a major cause of service calls.

Create an Air Gap 

If you have incoming coax the next thing you'll need is to make sure your modem and router are separate devices in order to put a solution in between them.  Any Ethernet cable plugged in to the cable provider's modem is a potential surge path so we have to find a way of isolating the cable modem from your computers and streamers.  Once that is done we have a couple of different solutions.

Ethernet to Fiber Converters

Air is a fantastic isolator, providing about 30kV / cm of isolation.  WiFi connected devices are  naturally immune to network cable surges but not as high performing as Ethernet.  We need a solution that is completely immune to network cable surges but as high performing as the cable modem.  The answer is to use fiber based network cable in between our modem and router.  Fiber uses light over glass or plastic conductor to send the network signal.  It has no metal componet at all and so is immune to electrical surges.  Optical cables can carry in excess of 10 Gbps, well in excess of most home Internet bandwidths and definitely overkill for anything short of a hotel.  More bandwidth does not make your audio streams sound better I promise. Just match what your modem provides, which is now usually 1 Gbps and you'll be fine.

Use a pair of Ethernet to Fiber converters with fiber in between them to block all incoming surges.  Should a surge enter from outside your modem and maybe even the first converter may fry but anything downstream of the fiber cable will be safe.  Make sure to have a high quality surge protector or UPS that your modem connects to.  This approach is the most complete protection you can get, but it comes at the cost of additional wall warts and cables.  The good news is that this method is 100% plug and play.  There's nothing to configure, no software to load or web page to sign into.  Plug everything together and it will work.

Make sure you physically separate your modem and router as well! Having one sitting on top of the other can provide a chassis to chassis surge path and defeat the entire purpose of this exercise.

Carefully check the cable requirements for your converters as there are multiple types/sizes of fiber which can be a little maddening.


 

Use a Medical Grade Isolator

A simpler alternative to the fiber converters is to use an isolator.   If you are an audiophile you may already be considering using a boutique Ethernet ground isolator.  I'm going to advise you to instead use a medical grade unit like this one.  They are sometimes cheaper than an audiophile marketed unit but these are thoroughly tested to add about 4kV of common mode isolation.  Some manufacturers call these "medical grade" others "hospital grade" because the standard is meant to apply in patient care situations.  What is important not the name but that they are tested to the IEC 60601-1 standard. Boutique units can be more expensive and lack high voltage testing.

Note that unfortunately in the rare case when there is a differential surge these units won't be as effective as the fiber approach, but they completely avoid the mode conversion problem, and it's super easy to install. 

Which approach should I use? 

Personally I use all three approaches.  

  • Outside: Gas discharge coax protector at the grounding block
  • Between modem and router: Ethernet to fiber conversion with a two meter physical gap between them
  • At the end of long (20' or more) Ethernet runs inside the house:  Medical-grade Ethernet isolators

The potential for the largest surge generation is a strike that strikes and travels through an outside cable or piece of equipment.  That's where I have the highest and redundant surge protection.  

The next danger area is for an outside surge to come in through magnetic coupling.  This is why I use isolators at the end of long runs.

Of course if your equipment is expensive, you like having perfect ground isolation, or say you are running the network to another building running fiber instead of Ethernet may be a good choice.


What if I use Fiber or 5G Internet? 

These types of connections are inherently immune to surges from the Internet provider but long Ethernet runs inside can act like antennas.  The longer the run the more likely they can induce a surge.  For these cases putting a medical grade isolator at the farthest end from the router is probably your best form of protection.


Should I really not trust my surge strip?

If you follow my blog you know how big of a fan I am of Furman power conditioners with SMP and LiFT for surge protection as well as noise filtering.  They are still the very best you can get, and still I think you need to avoid any built-in Ethernet protectors.  The surge technology used for Ethernet is not the same as for power and based on outdated understanding of Ethernet surges.  Honestly researchers are still working on developing better understanding  of how Ethernet surges happen and only in the 21st century has this moved forward.  Furman's Ethernet protection doesn't take this research into account.  The AC power conditioning and surge protection is still state-of-the-art however.


Thursday, July 4, 2024

Upgrade Coils in Crossovers

Not too long ago in Audiogon a user launched a series of personal attacks vaguely based on his misguided and incomplete understanding of inductors and their use in a crossover.  In particular, the user felt that reducing the DC resistance of a coil was always a good thing and that no other considerations mattered.  One of the comments I read was "when we learned about filters we only cared about inductance and capacitance, not resistance."  Well, I'm sorry that their knowledge was incomplete but no reason to get personal because of that.

Here we'll discuss the subtleties of upgrading a coil with particular attention to the issue of DCR. 


DC Resistance

DC resistance is present in every inductor.  If you have only taken a basic AC circuit theory course you may never have even read about it, but it becomes a meaningful topic in more advanced classes.  An inductor is just a wire wrapped into a coil.  All wires have some resistance and all the rules of wire resistance apply to DCR: 

  • Larger gauges have lower R per foot/meter
  • Smaller gauges have higher R per foot/meter
  • Longer wires have more R
  • Shorter wires have less R

Further, inductance is proportional to the length of the wire, so higher inductance coils tend to have longer wire lengths and therefore higher R unless we compensate for it with larger wire gauges.  Finally, inductors have a maximum power associated with them.  Just like a resistor or wire they can melt if overheated. 

If you learned about coils in line level circuits your instructor may have skipped discussing DCR because the circuit impedance are often in the tens of kilo ohms.  In those cases the DCR of even a few ohms becomes irrelevant. In speakers with typical woofers having an Re of around 4 Ohms however small values matter.

Sample Crossover

For this practical example we'll use the JBL L82 crossover, provided below.  It's not particularly interesting except that it's a commercial speaker and the inductor DCR is fully documented.

 JBL L82 schematic.png 

For our simulation we'll only use the low pass filter, and we'll assume the speaker is a pure 4 Ohm resistor.  Sadly what we don't have is the speaker impedance data but it doesn't matter as we want to talk about general effects and issues. 

Take a look at the two inductors at the top.  The bar indicates ferrite core inductors.  1.8mH with 0.4 Ohms DCR.  In a crossover, the DCR specification is not a "maximum" but an expected value.  In case of failure a technician should attempt to replace the inductor with the same mH and DCR as specified. To model this AC behavior properly we'd imagine that we have an ideal coil followed by an ideal resistor: 

 

 

It is a simple fact that all inductors have some DCR.  All caps have some equivalent series resistance (ESR), and most resistors may have some parasitic inductance or capacitance unless especially designed not to.   We just ignore them until we are forced to think about them.  

In crossover design the DCR and ESR are important parts of the outcome, but may be more or less important in some places than others. 

In any event, lets take a look at the "transfer function" of the low pass filter with and without any DCR in the two ferrite coils: 


 

The term "transfer function" just means that we are looking at how the crossover affects the voltage that actually reaches the speaker.  The green line, above, represents the original low-pass filter while the blue represents the new "improved" version.   

As you can see the reduced DCR has changed the response of the filter, bumping up the output by about 1.5 dB at 20 Hz.  

The upgrade has now changed the tilt of the bass filter and speaker and altered the tonal balance, starting a domino effect. In order to keep the original speakers tonal balance  we now need to alter the low pass filter so it tilts down less (if possible) and adjust the high pass level.  We've now proven that it's incorrect to assume that cutting the DCR of a coil has no effect on the tonal balance.  This speaker will sound different, because it IS different.  You've now made a very different speaker than you started with and have to grapple with new sets of choices:

  • Accept the reduced DCR and new tonal balance (and system impedance, below)
  • Attempt to adjust the tonal balance and rethink the crossover, which means entirely different inductor values
  • Add series resistance to maintain the original tonal balance without any more crossover changes. 

 


DCR and System Impedance

For our example this will also affect the system impedance curve, in this case lowering the impedance by almost 1 Ohm: 


Critical DCR

On a practical note, components in series with a driver are less critical than those that shunt to ground.  In those the DCR is a critical value.  In even ordered filter components we often see an actual resistor with a very small value in series with a coil or capacitor, like this: 
 
 
 
In the case of L3, if we were to make significant reductions in the DCR without compensating with additional R in R3 we could accidentally end up with a very low minimum system impedance.  It's not an obvious thing as this change could affect the minimum impedance of the low pass section.   It's also possible that you alter the FR of the high pass filter significantly by making this change.
 
Similar issues can arise when upgrading old speakers with eletrolytic caps and high ESR.  A change here can really alter the system impedance curve in amplifier melting ways.  

Looking at the original schematic we see two coils in the HP filter section as well.  The DCR is specified and these are critical values.  While we may not be able to find exact matches we'd be well served by getting as close as possible OR compensating with additional R values in series.

Baffle Step Compensation

Lastly, advanced speaker designers like Troels Gravesen and others have been known to cheat a little by using the DCR as part of the baffle step compensation.  Reducing DCR can actually point the woofer impedance upwards instead of down. 

Avoiding Surprises 

The best approach is to understand the circuits you are working on. Measure the impedance of the entire speaker, the drivers and the individual components before making major investments in upgrading parts.  For simulation I like to use XSim but VituixCAD is also a free and popular option.  To measure impedance values (including DCR and ESR) I like to use Dayton DATS V3.  

Conclusion

My point is not whether you should/should not reduce the DCR of your speaker inductors but that you should be aware that changing the DCR of a coil has consequences which are material to the frequency and impedance of the final speaker and that you may be much better off doing more research into your existing speaker before proceeding down an upgrade path.